3305.xml
11.5 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
<?xml version="1.0" encoding="UTF-8"?>
<!-- BSD-3 Clause License
Copyright 2019 Open Mobile Alliance.
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its
contributors may be used to endorse or promote products derived
from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
-->
<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd">
<Object ObjectType="MODefinition">
<Name>Power Measurement</Name>
<Description1>This IPSO object should be used over a power measurement sensor to report a remote power measurement. It also provides resources for minimum/maximum measured values and the minimum/maximum range for both active and reactive power. It also provides resources for cumulative energy, calibration, and the power factor.</Description1>
<ObjectID>3305</ObjectID>
<ObjectURN>urn:oma:lwm2m:ext:3305:1.1</ObjectURN>
<LWM2MVersion>1.0</LWM2MVersion>
<ObjectVersion>1.1</ObjectVersion>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Resources>
<Item ID="5800">
<Name>Instantaneous active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>The current active power.</Description>
</Item>
<Item ID="5801">
<Name>Min Measured active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>The minimum active power measured by the sensor since it is ON.</Description>
</Item>
<Item ID="5802">
<Name>Max Measured active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>The maximum active power measured by the sensor since it is ON.</Description>
</Item>
<Item ID="5803">
<Name>Min Range active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>The minimum active power that can be measured by the sensor.</Description>
</Item>
<Item ID="5804">
<Name>Max Range active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>The maximum active power that can be measured by the sensor.</Description>
</Item>
<Item ID="5805">
<Name>Cumulative active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>Wh</Units>
<Description>The cumulative active power since the last cumulative energy reset or device start.</Description>
</Item>
<Item ID="5806">
<Name>Active Power Calibration</Name>
<Operations>W</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>Request an active power calibration by writing the value of a calibrated load.</Description>
</Item>
<Item ID="5810">
<Name>Instantaneous reactive power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>var</Units>
<Description>The current reactive power.</Description>
</Item>
<Item ID="5811">
<Name>Min Measured reactive power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>var</Units>
<Description>The minimum reactive power measured by the sensor since it is ON.</Description>
</Item>
<Item ID="5812">
<Name>Max Measured reactive power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>var</Units>
<Description>The maximum reactive power measured by the sensor since it is ON.</Description>
</Item>
<Item ID="5813">
<Name>Min Range reactive power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>var</Units>
<Description>The minimum active power that can be measured by the sensor.</Description>
</Item>
<Item ID="5814">
<Name>Max Range reactive power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>var</Units>
<Description>The maximum reactive power that can be measured by the sensor.</Description>
</Item>
<Item ID="5815">
<Name>Cumulative reactive power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>varh</Units>
<Description>The cumulative reactive power since the last cumulative energy reset or device start.</Description>
</Item>
<Item ID="5816">
<Name>Reactive Power Calibration</Name>
<Operations>W</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>var</Units>
<Description>Request a reactive power calibration by writing the value of a calibrated load.</Description>
</Item>
<Item ID="5820">
<Name>Power factor</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>If applicable, the power factor of the current consumption.</Description>
</Item>
<Item ID="5821">
<Name>Current Calibration</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Read or Write the current calibration coefficient.</Description>
</Item>
<Item ID="5822">
<Name>Reset Cumulative energy</Name>
<Operations>E</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type></Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Reset both cumulative active/reactive power.</Description>
</Item>
<Item ID="5605">
<Name>Reset Min and Max Measured Values</Name>
<Operations>E</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type></Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Reset the Min and Max Measured Values to Current Value.</Description>
</Item>
<Item ID="5750">
<Name>Application Type</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The application type of the sensor or actuator as a string depending on the use case.</Description>
</Item>
<Item ID="5518">
<Name>Timestamp</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Time</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The timestamp of when the measurement was performed.</Description>
</Item>
<Item ID="6050">
<Name>Fractional Timestamp</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration>0..1</RangeEnumeration>
<Units>s</Units>
<Description>Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).</Description>
</Item>
<Item ID="6042">
<Name>Measurement Quality Indicator</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration>0..23</RangeEnumeration>
<Units></Units>
<Description>Measurement quality indicator reported by a smart sensor. 0: UNCHECKED No quality checks were done because they do not exist or can not be applied. 1: REJECTED WITH CERTAINTY The measured value is invalid. 2: REJECTED WITH PROBABILITY The measured value is likely invalid. 3: ACCEPTED BUT SUSPICIOUS The measured value is likely OK. 4: ACCEPTED The measured value is OK. 5-15: Reserved for future extensions. 16-23: Vendor specific measurement quality.</Description>
</Item>
<Item ID="6049">
<Name>Measurement Quality Level</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration>0..100</RangeEnumeration>
<Units></Units>
<Description>Measurement quality level reported by a smart sensor. Quality level 100 means that the measurement has fully passed quality check algorithms. Smaller quality levels mean that quality has decreased and the measurement has only partially passed quality check algorithms. The smaller the quality level, the more caution should be used by the application when using the measurement. When the quality level is 0 it means that the measurement should certainly be rejected.</Description>
</Item>
</Resources>
<Description2></Description2>
</Object>
</LWM2M>