3388.xml
7.97 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
<?xml version="1.0" encoding="UTF-8"?>
<!-- BSD-3 Clause License
Copyright 2019 Zumtobel Group.
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its
contributors may be used to endorse or promote products derived
from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
-->
<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M-v1_1.xsd">
<Object ObjectType="MODefinition">
<Name>oA Device</Name>
<Description1><![CDATA[The 'oA Device' represents the OpenAIS specific parameters of a Device that are necessary in addition to the LWM2M Device.]]></Description1>
<ObjectID>3388</ObjectID>
<ObjectURN>urn:oma:lwm2m:ext:3388</ObjectURN>
<LWM2MVersion>1.1</LWM2MVersion>
<ObjectVersion>1.0</ObjectVersion>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Resources>
<Item ID="4001">
<Name>ObjectVersion</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description><![CDATA[LWM2M Object versioning label.]]></Description>
</Item>
<Item ID="901">
<Name>Documentary Description</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration>0..256 bytes</RangeEnumeration>
<Units></Units>
<Description><![CDATA[Resource to hold a documentary text description of the object.]]></Description>
</Item>
<Item ID="907">
<Name>Error Status</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Unsigned Integer</Type>
<RangeEnumeration>0..65535</RangeEnumeration>
<Units></Units>
<Description><![CDATA[Error status is a bit coded value that shows all current errors on the object. The error status changes as soon as a new error occurs or an old one is resolved. Bitwise: 0 (LSB): Communication_Error, 1: Power_Supply_Error, 2: Firmware_Error, 3: Over_Temperature, 4: Vendor_Specific_Error_1, 5: Vendor_Specific_Error_2, 6: Vendor_Specific_Error_3, 7: Vendor_Specific_Error_4, 8: Vendor_Specific_Error_5, 9: Vendor_Specific_Error_6, 10: Vendor_Specific_Error_7, 11: Vendor_Specific_Error_8, 12: Vendor_Specific_Error_9, 13: Vendor_Specific_Error_10, 14: Vendor_Specific_Error_11, 15: Vendor_Specific_Error_12]]></Description>
</Item>
<Item ID="500">
<Name>OEM ID</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration>0..64 bytes</RangeEnumeration>
<Units></Units>
<Description><![CDATA[OEM ID: Identifies the OEM product (using its GTIN) that has this (electronic) device built in]]></Description>
</Item>
<Item ID="501">
<Name>OEM String</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration>0..64 bytes</RangeEnumeration>
<Units></Units>
<Description><![CDATA[Human readable OEM ID, e.g. the OEM company and product name that has this (electronic) device built in]]></Description>
</Item>
<Item ID="929">
<Name>BMS ID</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Unsigned Integer</Type>
<RangeEnumeration>0..65535</RangeEnumeration>
<Units></Units>
<Description><![CDATA[ID to be used in BMS: identifies the devices role in the (BMS) system]]></Description>
</Item>
<Item ID="503">
<Name>CPU Temperature</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Integer</Type>
<RangeEnumeration>-128..127</RangeEnumeration>
<Units>C</Units>
<Description><![CDATA[Current temperature of the CPU]]></Description>
</Item>
<Item ID="504">
<Name>Executing Objects</Name>
<Operations>R</Operations>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Corelnk</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description><]]></Description>
</Item>
<Item ID="910">
<Name>Total Energy Usage</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Unsigned Integer</Type>
<RangeEnumeration>0..18446744073709551615</RangeEnumeration>
<Units>Ws</Units>
<Description><![CDATA[The total energy usage of the device (accumulated value)]]></Description>
</Item>
<Item ID="911">
<Name>Actual Power Usage</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Unsigned Integer</Type>
<RangeEnumeration>0..4294967295</RangeEnumeration>
<Units>W</Units>
<Description><![CDATA[The actual power usage of the device. Scaling is 0.1W / unit]]></Description>
</Item>
<Item ID="912">
<Name>Accuracy Class</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration>0..64 bytes</RangeEnumeration>
<Units></Units>
<Description><![CDATA[The accuracy class of the energy sensor on the device (using either % accuracy or a letter that defines the accuracy class)]]></Description>
</Item>
<Item ID="908">
<Name>Mounting Location</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>String</Type>
<RangeEnumeration>1..64 bytes</RangeEnumeration>
<Units></Units>
<Description><![CDATA[Describes the location of the device within the building. The content of the string is site specific.]]></Description>
</Item>
<Item ID="505">
<Name>System Failure Time</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Unsigned Integer</Type>
<RangeEnumeration>0..65535</RangeEnumeration>
<Units>ms</Units>
<Description><![CDATA[When the Object is not able to communicate with a control function in the network, in this case for a period of 10s, the connection is considered lost and the light point automatically sets to the value indicated in 'System Failure Intensity'.]]></Description>
</Item>
</Resources>
<Description2><![CDATA[]]></Description2>
</Object>