3423.xml
5.89 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
<?xml version="1.0" encoding="UTF-8"?>
<!-- BSD-3 Clause License
Copyright 2020 uCIFI Alliance
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its
contributors may be used to endorse or promote products derived
from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
-->
<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd">
<Object ObjectType="MODefinition">
<Name>Gas meter</Name>
<Description1>The uCIFI gas meter measures the volume of gas that was distributed through the gas meter, in pulse count and/or in m3. It also detects anomalies in the gas meter.</Description1>
<ObjectID>3423</ObjectID>
<ObjectURN>urn:oma:lwm2m:ext:3423</ObjectURN>
<LWM2MVersion>1.0</LWM2MVersion>
<ObjectVersion>1.0</ObjectVersion>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Resources>
<Item ID="1">
<Name>Cumulated gas volume</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>m3</Units>
<Description>Number of cubic meters of gas distributed through the meter since last reset.</Description>
</Item>
<Item ID="2">
<Name>Cumulated gas meter value reset</Name>
<Operations>E</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type></Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Reset the cumulated meter value.</Description>
</Item>
<Item ID="3">
<Name>Type of meter</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Type of gas meter.</Description>
</Item>
<Item ID="4">
<Name>Cumulated pulse value</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Cumulated number of pulses detected on the gas meter.</Description>
</Item>
<Item ID="5">
<Name>Cumulated pulse value reset</Name>
<Operations>E</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type></Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Reset the cumulated pulse value.</Description>
</Item>
<Item ID="6">
<Name>Pulse ratio</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Ratio to calculate gas volume from pulse value.</Description>
</Item>
<Item ID="7">
<Name>Minimum flow rate</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>m3/s</Units>
<Description>Minimum flow rate since last metering value.</Description>
</Item>
<Item ID="8">
<Name>Maximum flow rate</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>m3/s</Units>
<Description>Maximum flow rate since last metering value.</Description>
</Item>
<Item ID="9">
<Name>Leak suspected</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if gas leak is suspected.</Description>
</Item>
<Item ID="10">
<Name>Leak detected</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if gas leak is detected.</Description>
</Item>
<Item ID="11">
<Name>High temperature</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if high temperature is detected around the gas meter.</Description>
</Item>
</Resources>
<Description2></Description2>
</Object>
</LWM2M>