3418.xml
13.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
<?xml version="1.0" encoding="UTF-8"?>
<!-- BSD-3 Clause License
Copyright 2020 uCIFI Alliance
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its
contributors may be used to endorse or promote products derived
from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
-->
<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd">
<Object ObjectType="MODefinition">
<Name>Electrical monitor</Name>
<Description1>The uCIFI electrical monitor object provides attributes related to the analysis of electrical consumption in an outdoor luminaire or in a streetlight cabinet. It also identifies electrical anomalies.</Description1>
<ObjectID>3418</ObjectID>
<ObjectURN>urn:oma:lwm2m:ext:3418</ObjectURN>
<LWM2MVersion>1.0</LWM2MVersion>
<ObjectVersion>1.0</ObjectVersion>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Resources>
<Item ID="1">
<Name>Supply voltage</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>V</Units>
<Description>Electrical voltage supplied to the device.</Description>
</Item>
<Item ID="2">
<Name>Supply current</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>A</Units>
<Description>Electrical current supplied to the device.</Description>
</Item>
<Item ID="3">
<Name>Frequency</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>Hz</Units>
<Description>Frequency of the supply current to the device.</Description>
</Item>
<Item ID="4">
<Name>Active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>Active power consumed by the device and its electrical load.</Description>
</Item>
<Item ID="5">
<Name>Power factor</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration>-1..1</RangeEnumeration>
<Units></Units>
<Description>Power factor is equal to active power divided by apparent power. The value is between -1 and +1.</Description>
</Item>
<Item ID="6">
<Name>Cumulated active energy</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>kWh</Units>
<Description>Cumulated number of kWh measured by the device and its load since last energy counter reset.</Description>
</Item>
<Item ID="7">
<Name>Energy reset</Name>
<Operations>E</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type></Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Reset both cumulated active and reactive energy counter.</Description>
</Item>
<Item ID="8">
<Name>Low power factor threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Threshold below which the device should trigger a low power factor event.</Description>
</Item>
<Item ID="9">
<Name>Low power factor</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the power factor is below threshold. This is an absolute value threshold.</Description>
</Item>
<Item ID="10">
<Name>Low power threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>Threshold below which the device should trigger a low power event.</Description>
</Item>
<Item ID="11">
<Name>Low power threshold at low dim level</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>Threshold below which the device should trigger a low power event. This is an addition to the low power threshold to allow a separated threshold when dim level is low.</Description>
</Item>
<Item ID="12">
<Name>Low power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the power is below threshold. Vendor may consider the Low power threshold at low dim level to set this resource to True, taking into account the lamp dim level.</Description>
</Item>
<Item ID="13">
<Name>High power threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>Threshold above which the device should trigger a high power event.</Description>
</Item>
<Item ID="14">
<Name>High power threshold at low dim level</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>W</Units>
<Description>Threshold above which the device should trigger a high power event. This is an addition to the high power threshold to allow a separated threshold when dim level is low.</Description>
</Item>
<Item ID="15">
<Name>High power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the power is above threshold. Vendor may consider the High power threshold at low dim level to set this resource to True, taking into account the lamp dim level.</Description>
</Item>
<Item ID="16">
<Name>Low current threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>A</Units>
<Description>Threshold below which the device should trigger a low current event.</Description>
</Item>
<Item ID="17">
<Name>Low current</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the current is below threshold.</Description>
</Item>
<Item ID="18">
<Name>High current threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>A</Units>
<Description>Threshold above which the device should trigger a high current event.</Description>
</Item>
<Item ID="19">
<Name>High current</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the current is above threshold.</Description>
</Item>
<Item ID="20">
<Name>Low voltage threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>V</Units>
<Description>Threshold below which the device should trigger a low voltage event.</Description>
</Item>
<Item ID="21">
<Name>Low voltage</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the voltage is below threshold.</Description>
</Item>
<Item ID="22">
<Name>High voltage threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration>ON;OFF</RangeEnumeration>
<Units>V</Units>
<Description>Threshold above which the device should trigger a high voltage event.</Description>
</Item>
<Item ID="23">
<Name>High voltage</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the voltage is above threshold.</Description>
</Item>
<Item ID="24">
<Name>Critical inrush threshold</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>A</Units>
<Description>Threshold above which the device should trigger a critical inrush event.</Description>
</Item>
<Item ID="25">
<Name>Critical inrush current</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Set to True if the inrush current is above threshold.</Description>
</Item>
<Item ID="26">
<Name>Minimum inrush Current</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>A</Units>
<Description>Minimum inrush current since last configuration.</Description>
</Item>
<Item ID="27">
<Name>Maximum inrush Current</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>A</Units>
<Description>Maximum inrush current since last configuration.</Description>
</Item>
<Item ID="28">
<Name>Latest inrush Current</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>A</Units>
<Description>Latest inrush current measured since last time the relay switched ON.</Description>
</Item>
<Item ID="29">
<Name>Reactive power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>var</Units>
<Description>Instantaneous reactive power measured by the device and its electrical load.</Description>
</Item>
<Item ID="30">
<Name>Reactive energy</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>varh</Units>
<Description>Cumulative reactive power measured by the device and its electrical load since last energy counter reset.</Description>
</Item>
</Resources>
<Description2></Description2>
</Object>
</LWM2M>